2 error messages, 1 if a malfunction occurs, 2 error codes – Avery Dennison ALS 380 User Manual

Page 80: 1 if a malfunction occurs 6.2.2 error codes, Als 380

Advertising
background image

78

6

O

PERATIONAL

MALFUNCTIONS

6.2 E

RROR

MESSAGES

ALS

380

6.2.1

If a malfunction occurs

If the control system detects a serious error:
– The labelling operation is stopped.
– An error code is displayed on the operator panel.

If the cause of the error has been eliminated:

Acknowledge the error message by pressing the
ENTER key.

6.2.2

Error codes

Message

Description

Possible causes and remedies

E__1

The loop space is not filled.

Label roll empty:

Replace label roll.

Pressure roller not closed:

Swing up the pressure roller on the drive roller unit’s un-
wind unit and return it to its position pressing against the
roller. The pressure roller clicks neatly into its operating
position.

Unwind unit drive defective:
– Repair by servicing technician is required; refer to

Service Guide

The photoelectric sensor in the loop
space does not actuate.

Reflective surface is dirty:

Clean the reflective surface.

Use of very bright labels or
Sensor potentiometer out of adjustment or
Sensor defective:
– Adjustment/replacement by servicing technician is

required; refer to Service Guide

6.2

ERROR MESSAGES

Advertising