Als 380, Perational, Malfunctions – Avery Dennison ALS 380 User Manual

Page 79: Arning, Messages

Advertising
background image

77

6

O

PERATIONAL

MALFUNCTIONS

6.1 W

ARNING

MESSAGES

ALS

380

W__2

Memory errors
Factory settings are activated, see
appendix.

CPU battery is discharged after a long shut-down period of
the machine:

➔

Leave the machine switched on for some time to re-
charge the battery

If the accumulatorerror occurs frequently:

➔

Have the CPU battery replaced by the responsible
servicing technician.

Settings no longer available after software update.
Settings must be input again by a servicing techni-
cian; refer to Service Guide.

W__3

Too many labels between label stop
sensor and dispensing edge.

Label stop sensor must be adjusted by servicing
technician; refer to Service Guide.

W__4

Dispensing speed is too high.
This negatively affects position accu-
racy.

➔

Reduce dispensing speed (VELO), if the warning-
message is frequently displayed for long periods.

For automatic dispensing speed (APSF):
A check of the EGRA function by servicing techni-
cians is required; refer to the Service Guide

W__5

The roll diameter control (optional)
reports the end of the label roll.

➔

Insert new labelling material.

W__6

Data transmission error at the
V24 interface

The cables, plug connections, and interface param-
eters must be checked by servicing technicians; re-
fer to Service Guide

W__7

Label position on the product too
close to the product’s leading edge
and high dispensing speed

➔

Increase the setting value for POS, decrease dispensing
speed (VELO).

If this is not possible or the warning message
reappears:
The settings in the configuration menu must be
checked by servicing technicians; refer to Service
Guide
.

Message

Description

Possible causes and remedies

Advertising