Als 380, Perational, Malfunctions – Avery Dennison ALS 380 User Manual

Page 79: Arning, Messages

Advertising
background image

77

6

O

PERATIONAL

MALFUNCTIONS

6.1 W

ARNING

MESSAGES

ALS

380

W__2

Memory errors
Factory settings are activated, see
appendix.

CPU battery is discharged after a long shut-down period of
the machine:

Leave the machine switched on for some time to re-
charge the battery

If the accumulatorerror occurs frequently:

Have the CPU battery replaced by the responsible
servicing technician.

Settings no longer available after software update.
Settings must be input again by a servicing techni-
cian; refer to Service Guide.

W__3

Too many labels between label stop
sensor and dispensing edge.

Label stop sensor must be adjusted by servicing
technician; refer to Service Guide.

W__4

Dispensing speed is too high.
This negatively affects position accu-
racy.

Reduce dispensing speed (VELO), if the warning-
message is frequently displayed for long periods.

For automatic dispensing speed (APSF):
A check of the EGRA function by servicing techni-
cians is required; refer to the Service Guide

W__5

The roll diameter control (optional)
reports the end of the label roll.

Insert new labelling material.

W__6

Data transmission error at the
V24 interface

The cables, plug connections, and interface param-
eters must be checked by servicing technicians; re-
fer to Service Guide

W__7

Label position on the product too
close to the product’s leading edge
and high dispensing speed

Increase the setting value for POS, decrease dispensing
speed (VELO).

If this is not possible or the warning message
reappears:
The settings in the configuration menu must be
checked by servicing technicians; refer to Service
Guide
.

Message

Description

Possible causes and remedies

Advertising