6 if errors occur, Als 380 – Avery Dennison ALS 380 User Manual

Page 48

Advertising
background image

46

4

O

PERATION

4.2 S

ETTING

AND

MONITORING

ALS

380

4.2.6

If errors occur

Warning messages
If the machine control system detects a malfunction,
but the labelling operation does not have to be inter-
rupted:
– A warning message appears on the LED-indicator

of the operator panel.

– A warning message is displayed in the format

W_nn:
W stands for warning,
nn is a two-digit numerical code.

– An electronic signal is issued at the same time. The

signal can be further processed by an external con-
trol system.

– For an explanation of the warning messages and

notes on fault elimination, see chapter Operational
malfunctions
.

Example [50]:
– The current labelling speed is too high.
– The warning message W__4 appears on the opera-

tor panel.

– An electronic signal is sent to the system control.
– The system control issues an additional warning

tone.

[50] Example: The warning message W__4 is displayed on the op-

erator panel

Advertising