Scale motion level filter, Scale motion level filter -40 – Datalogic Scanning MAGELLAN 8500 User Manual

Page 146

Advertising
background image

6-40

Magellan

®

8500 Scanner

Scale Motion Level Filter

In environments where checkstands generate excessive vibration, the scale
can be set to filter a certain amount of the motion with regard to its oper-
ation.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan your selection from the bar codes below. You’ll need to cover

any unused bar codes on this and the facing page to ensure that
the scanner reads only the bar code you intend to scan. The strat-
egy is to select the lowest possible filter level needed that allows
normal scale operation.

3. Complete the programming sequence by scanning the SWITCH

bar code.

SCALE MOTION LEVEL FILTER = LOW

SCALE MOTION LEVEL FILTER = MEDIUM LOW

NOTE

This filter is generally used only in applications where scale error E_1 (too
much motion at power-up) has occurred.