Physical Parameters

This section provides specifications for performance, environmental and
electrical parameters. Reference the second section of this manual, Site
Preparation and Installation
, for physical measurements of all models and
some accessories.

Scanning

The scanner has a scan zone between the two windows where the scanner
projects laser light in order to scan items. Two separate projections, one
from the horizontal window and one from the vertical window, combine
to form a zone where bar code labels are read. Refer to the Operation and
Maintenance
section of this manual for more details about the topic: Scan-
ning Items
.

Weighing

Specifications for scale capacity, settling time, minimum and maximum
static weight, zeroing, and warm-up time are given below. For more infor-
mation regarding the topic: Proper Weighing Technique, refer to the Opera-
tion and Maintenance
section of this manual.

Rated Weight Capacity

The scale’s operational weight capacity is:

30.00 pounds, displayed in 0.01 increments

OR

15.000 kilograms

1

, displayed in 0.005 increments.

Minimum Increment

The minimum weight that can be accurately measured by the scale is 0.02
lb. (0.005 kg).

Maximum Static Weight (Overload)

A maximum static weight of 150 pounds (68 kg) can be sustained by the
scale without incurring damage or degrading performance.

1. The scale can also be set for 9.99 kg max.