6-206

Magellan

®

8500 Scanner

Code 128 Maximum Label Length

This feature specifies the maximum allowable length of a Code 128 label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code, SET CODE 128 MAXIMUM LABEL

LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that

represent the desired maximum label length. The selectable range
for this option is 01 to 80. Pad all single digit numbers with a
leading zero to yield a two-digit entry (01-80).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET CODE 128 MAXIMUM LABEL LENGTH

NOTE

Length in this case includes function characteres and data characters,
but does not include function code change or check character. This fea-
ture applies when Code 128 Length Control
is set to variable-length
decoding.

Maximum label length should be greater than or equal to minimum label
length.