F-13

Codabar

•

Check character must be included in label data.

•

Label length including check character and excluding prefix char-
acters must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.

•

Prefix must be ASCII characters ']F0'.

•

Start stop character sets must meet the matching requirement set
forth by the scanner configuration item Codabar Start Stop Char-
acter Match
.

•

Start stop character sets s must be of the form ABCD/ABCD
and must be included in the label.

•

Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the
example is a placeholder for the start stop character set).

MSI/Plessey

•

Check character must be included in label data.

•

Label length including check character and excluding prefix char-
acters must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.

•

Prefix must be ASCII characters ']M0'.

•

Example: ']M0144769254'.

Code 93

•

Prefix must be ASCII characters ']G0'.

•

Label length excluding prefix characters must meet requirements
imposed by the main scanner's fixed or variable label length con-
trol for this symbology type.

•

Example : ']G0Code93-test'.

RSS-14

•

Prefix must be ASCII characters ']e0'.

•

Check character must be included in label.

•

Label length excluding prefix characters must be 14 characters.

•

Example: ']e001044123456789'.