A number of situations require the scale to be calibrated. They are:

at initial installation of the scanner/scale

if the scale cannot be re-zeroed

if you change the weight measure from pounds to kilograms or
vice-versa

if diagnostics indicate a calibration error

the weigh module has been replaced

Follow the procedures on the following pages to ensure that the scanner/
scale will meet Weights and Measurement requirements.

Certification of the scanner/scale’s weighing apparatus is subject to
Federal, State and Local Weights and Measures statutes and is
restricted to authorized government agencies and/or duly registered
agents thereof. Anytime a scale is calibrated, it should be properly
sealed with a lead and wire or paper seal before being placed into ser-
vice.

It is your responsibility to check with the appropriate authorities in your
area to ensure compliance with pertinent regulations before removing
any official seals or placing a newly calibrated scanner/scale into ser-
vice.