Scale Error Reporting

Scale diagnostics uses the Remote Scale Display and the Zero Status lamp
to communicate specific scale failures. The following chart shows the
Remote Display messages, the Scale Status lamp indication, the problem
that the scale is experiencing and what action should be taken. When
troubleshooting, always remember to check all cable connections first
before proceeding with other problem isolation steps.

Table 4-2. Scale Error Reporting

Remote

Display

Scale Status

Lamp

Problem

Description

Action Required

E _1

Flash, pause, 1 blink,
long pause, repeat
sequence.

Too much motion at power-
up.

Check for stable installation. Change
scale motion filter using the labels
found in Section 6; restart. If problem
persists, scale may require calibration.

E__2

Flash, pause, 2
blinks, long pause,
repeat sequence.

Calibration lost.

Call technical support personnel. Re-
calibrate; restart; recertify (if required).

E__3

Flash, pause, 3
blinks, long pause,
repeat sequence.

Scale communication lost.
Internal scanner/scale prob-
lem.

Call technical support personnel;
report error.

E__4

Flash, pause, 4
blinks, long pause,
repeat sequence.

Scale module failure.

Call technical support personnel;
report error.

E__5

Flash, pause, 5
blinks, long pause,
repeat sequence.

Internal software fault.

Call technical support personnel;
report error.

Other Scale Reporting

- 0 -

Off

Cannot zero at power- up or
weight remains on scale for
more than 4 minutes or
weight has not returned to
zero between POS weight
requests

a

.

- Check debris chutes.
- Verify that the weigh platter moves
freely.
- Remove item(s) from scale
- Press Scale Zero Push Button
- for more information.
- If the scale still fails to zero, recali-
brate the scale.

a. This is a configurable feature.