I 2 of 5 Fixed Length 2

This feature specifies I 2 of 5 second fixed length.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 2 below.

You’ll need to cover any unused bar codes on this and the facing
page to ensure that the scanner reads only the bar code you intend
to scan.

3. Scan the appropriate digits from the keypad in Appendix C that

represent the desired fixed label length. The selectable range for
this option is 00, or 02 to 50; even numbers only. Pad all single
digit numbers with a leading zero to yield a two-digit entry (02-
50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET I 2 OF 5 FIXED LENGTH 2

NOTE

This applies when I 2 of 5 Length Control is set to fixed-length decod-
ing.

If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.