Msi/plessey maximum label length, Msi/plessey maximum label length -256 – Datalogic Scanning MAGELLAN 8500 User Manual

Page 362

Advertising
background image

6-256

Magellan

®

8500 Scanner

MSI/Plessey Maximum Label Length

This feature specifies the maximum allowable length of an MSI/Plessey
label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code, SET MSI/PLESSEY MAXIMUM LABEL

LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that

represent the desired maximum label length. The selectable range
for this option is 4 to 16. Pad all single digit numbers with a lead-
ing zero to yield a two-digit entry (04-16).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET MSI/PLESSEY MAXIMUM LABEL LENGTH

NOTE

Length in this case includes check and data characters, but does not
include start, stop or full ASCII shift characters. This feature applies when
MSI/Plessey Length Control
is set to variable-length decoding.

Maximum label length should be greater than or equal to minimum label
length.