Codabar minimum label length, Codabar minimum label length -236 – Datalogic Scanning MAGELLAN 8500 User Manual

Page 342

Advertising
background image

6-236

Magellan

®

8500 Scanner

Codabar Minimum Label Length

This feature specifies the minimum allowable length of a Codabar label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code, SET CODABAR MINIMUM LABEL

LENGTH below. You’ll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that

represent the desired minimum label length. The selectable range
for this option is 03 to 50. Pad all single digit numbers with a
leading zero to yield a two-digit entry (03-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET CODABAR MINIMUM LABEL LENGTH

NOTE

Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when
Codabar Length Control
is set to variable-length decoding.

Minimum label length should be less than or equal to maximum label
length.