Datalogic Handheld Data Format Requirements

The following sections describe label transmission formats that are typi-
cally observed in factory configurations of Datalogic handheld scanners.

RSS-14

•

Prefix must be ASCII characters ‘R4’

•

Check character must be included in label

•

Application identifier “01” must follow the prefix and preceed the
base label

•

Label length excluding prefix characters must be 16 characters.

•

Example: ‘R40101044123456789’

RSS Expanded

•

Prefix must be ASCII characters ‘R4’

Check character must be included in label

UPC-A

•

Number system must be included in label data.

•

Check digit must be included in label data and is assumed to be
correct.

•

Prefix must be an ASCII character 'A' - total length including
prefix must be 13.

•

Example: 'A060992011187'.

UPC-A with 2-Digit Supplemental

•

Number system must be included in label data.

•

Check digit must be included in label data and is assumed to be
correct.

•

Supplemental data is appended to base label.

•

Prefix must be an ASCII character 'A' - total length including
prefix must be 15.

•

Example: 'A06099201118712'.