Rss expanded label id, Rss expanded label id -185 – Datalogic Scanning 9500 User Manual

Page 301

Advertising
background image

RSS Expanded Enable

Product Reference Guide

6-185

RSS Expanded Label ID

This feature specifies an RSS Expanded label ID to be added to bar code
data.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET RSS EXPANDED LABEL ID

below. You’ll

need to cover any unused bar codes on this and the facing page to
ensure the scanner reads only the bar code you intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired Label ID characters; entered as two hex pairs. A
table containing the

ASCII Character Set

and their corresponding

Hex Values is available in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal
digits for each character. Thus, to set a two-character value of AB,
bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned.
The selectable range for this option is any hex value from 00 to FF.

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET RSS EXPANDED LABEL ID

NOTE

The programming feature,

RS-232 Label ID Control, designates whether the

Label ID is transmitted as a prefix or suffix or if Label ID is disabled.