Code 39 maximum label length, Code 39 maximum label length -199, Code – Datalogic Scanning 9500 User Manual

Page 315: 39 maximum label length and

Advertising
background image

Code 39 Enable

Product Reference Guide

6-199

Code 39 Maximum Label Length

This feature specifies the maximum allowable length of a Code 39 label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET CODE 39 MAXIMUM LABEL LENGTH

below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired maximum label length. The selectable range for
this option is 00 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET CODE 39 MAXIMUM LABEL LENGTH

NOTE

Length in this case includes check, data and ASCII characters, but does not
include start, or stop characters. This feature applies when

Code 39 Length

Control is set to variable-length decoding.

Maximum label length should be greater than or equal to minimum label
length.