Codabar Minimum Label Length

This feature specifies the minimum allowable length of a Codabar label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET CODABAR MINIMUM LABEL LENGTH

below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired minimum label length. The selectable range for
this option is 03 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (03-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET CODABAR MINIMUM LABEL LENGTH

NOTE

Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when

Coda-

bar Length Control is set to variable-length decoding.

Minimum label length should be less than or equal to maximum label length.