Msi/plessey stitching, Msi/plessey stitching -268 – Datalogic Scanning 9500 User Manual

Page 384

Advertising
background image

6-268

Magellan

®

9500

MSI/Plessey Stitching

Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/
Plessey bar code are presented to the scanner with this feature enabled, the
bar code parts will be assembled by the scanner’s software, and the data
will be decoded if all bar code proofing requirements are met.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan your selection from the bar codes below. You’ll need to cover

any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.

3. Complete the programming sequence by scanning the SWITCH

bar code.

MSI/PLESSEY STITCHING = DISABLE

MSI/PLESSEY STITCHING = ENABLE

NOTE

MSI/Plessey Stitching operates using fixed lengths ONLY. MSI/Plessey Fixed
Length 1 and/or MSI/Plesse
y Fixed Length 2 must be properly configured for
stitching to work.