Compuprint 6314/6414 - User Manual

Fig. 25 – Paper sensor adjustment knob

Perform the TOF sensor Calibrate procedure described below whenever a different type of media
sensing will be required (Transmissive or Reflective), when installing never-before-tried media, or
when the printer is experiencing loss of TOF position. Loss of Top-of-Form is usually followed by
a fault message on the LCD, such as “PAPER FAULT” or “PAPER OUT”.

2.4.3 Running The Calibrate Via The Menu

Sequence Of Operations


The printer is equipped with a paper sensor which is necessary for perfect alignment of the paper
under the print head.

Sequence of operations necessary for a correct calibration:
- To select what the paper sensor must be calibrate (Transmissive / Reflective).
- Remove paper and Run No Paper Calibration.
- Insert paper
- To move the paper sensor, using the appropriate knob, in a label zone where there aren’t any

printed logos or bar code etc.

- Run Automatic Adjustment.
-

NOTE!

Run No Paper Calibration function is necessary only:

1) at the first time we install the printer.

2) when we update the firmware.

3) when the printer come back from the repair center.

See the chapter 3.9 (Diagnostic Menu) for details.