4 front panel led indicators -3, 5 parameter setup -3 – Comtech EF Data DD240XR Rev Е User Manual

Page 23

Advertising
background image

DD240XR High-Speed Digital Demodulator

User Interfaces

MN-DD240XR – Rev. E

4-3

4.1.4 Front Panel LED Indicators


Eight LEDs on the DD240XR Front Panel (Refer to Table 4-3) indicate the status of the
DD240XRs operation. The LED colors maintain a consistent meaning. Green signifies that the
indication is appropriate for normal operation. Yellow means that there is a condition not proper
for normal operation, and Red indicates a fault condition that will result in lost communications.

Table 4-3.

LED

Color

Function

Carrier Lock

Green

Indicates the DD240XR Demodulator and Decoder are
locked.

Major Alarm

Red

Indicates that the receive direction has failed, losing traffic.

Minor Alarm

Yellow

Indicates a receive warning condition exists.

Test Mode

Yellow

Indicates the demodulator is involved in current test mode
activity.

Power

Green

Indicates the DD240XR unit is currently powered up.

Fault

Red

Indicates a common fault exists such as power out of spec.

Event

Yellow

Indicates that the events have been logged into the event
buffer.

Remote

Green

Indicates that the unit is set to respond to the remote control
or terminal input.


4.1.5 Parameter Setup


The four arrow keys (

↑), (↓), (→), (←), to the right of the LCD display are used to navigate the

menu tree and select the parameter to be set. After arriving at a parameter that needs to be
modified, depress <ENTER>. The first space of the modifiable parameter highlights (blinks) and
is ready for a new parameter to be entered. After entering the new parameter using the keypad
(Refer to Figure 4-3), depress <ENTER> to lock in the new parameter. If a change needs to be
made prior to pressing <ENTER>, depress <CLEAR> and the display defaults back to the original
parameter. Depress <ENTER> again and re-enter the new parameters followed by <ENTER>.

Following a valid input, the DD240XR will place the new setting into the nonvolatile SRAM making
it available immediately and available the next time the unit is powered-up.