buffUnderflow(1),
buffNearEmpty(2),
buffNearFull(3),
buffOverflow(4),
excClock(5),
excPllLock(6),
demodLock(7),
ifecLock(8),
ofecLock(9),
frameSync(10),
ebno(11),
terrEthDestIp(12),
terrEthLinkStatus(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
A bit field. Minor alarms allowed.
"
::= { alarms 4 }

commonAlarms OBJECT-TYPE
SYNTAX BITS {
plus5V(0),
plus12V(1),
neg12V(2),
plus24V(3),
temperature(4),
lnbV(5),
demodHwFault(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.

1 indicates an alarm condition
temperature(3) is reserved and not currently updated
"
::= { alarms 5 }

commonAlarmsAllowed OBJECT-TYPE
SYNTAX BITS {
plus5V(0),
plus12V(1),
neg12V(2),
plus24V(3),
temperature(4),
lnbV(5),
demodHwFault(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
A bit field. Common alarms allowed.

temperature(3) is reserved and not currently updated. It is recommended that this
bit always be disallowed.
"
::= { alarms 6 }

latchedMajorAlarms OBJECT-TYPE
SYNTAX BITS {
signalLock(0),