Comtech EF Data DD240XR Rev Е User Manual

Page 80

Advertising
background image

User Interfaces

DD240XR High-Speed Digital Demodulator

4-60

MN-DD240XR – Rev. E

"
The estimated Bit Error Rate after the outside forward error correction has been applied.
This number is actually the exponent, exp, of the equation Mx10^exp.
There is an implied decimal point.

Example: a value of -3 represents a Mx10^-3
Extended Example: a mantissa value of 27 and an exponent value of -34 indicates 2.7E-34
"
::= { monitor 14 }

rxBufferLevel OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The percentage full value of the receive buffer.
There is an implied decimal point.

Example: a value of 94 represents 94% full.
"
::= { monitor 15 }

radTerrEthPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
unresolved(1),
half_10m(2),
half_100m(3),
full_10m(4),
full_100m(5),
half_1gig(6),
full_1gig(7)
}
ACCESS read-only
STATUS current
DESCRIPTION
"Shows the link status of the active Gig Ethernet card."
::= { monitor 16 }

radTerrEthTotalPkts OBJECT-TYPE

SYNTAX Counter32
ACCESS read-only
STATUS current
DESCRIPTION
"Total packet count for the Gig Ethernet card."
::= { monitor 17 }

radTerrEthFecColPkts OBJECT-TYPE

SYNTAX Counter32
ACCESS read-only
STATUS current
DESCRIPTION
"FEC column packet count for the Gig Ethernet card."
::= { monitor 18 }

radTerrEthClrStats OBJECT-TYPE
SYNTAX INTEGER {
toggle0(0),
toggle1(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Clears the Gig Ethernet card statistics."
::= { monitor 19 }

Advertising