Opcode: <2440h>

Query Test Status

Response

<1>

<1>

<1>


<1>


<8>


<8>

<2>


<2>


<4>

Test Pattern

Test Sync

Test Early Sync
Loss

Test Pattern
Sense

Test Pattern
Error Count

Test Bit Count

Test Pattern
BER Mantissa

Test Pattern
BER Exponent

Test Run Time

0 = none, 1 = (2

15

-1), 23=(2

23

-1)


0 = false, 1=true

0 = false, 1=true


0= normal, 1= inverted


bits


bits

with implied decimal point 493 = 4.93


exponent, -6 = 10

-6



seconds


Opcode: <2A00h>

Set Configuration

Same as Configuration Bytes from Opcode: <2401h> Query
Configuration and Status


Opcode: <2A01h>

Set frequency

<4>

Carrier
Frequency

in 1 Hz steps, If range = 50 MHz to 180 MHz, L-Band Range =

950 MHz to 2150 MHz


Opcode: <2A02h>

Set data rate

<4>

Data Rate

in 1 bps steps


Opcode: <2A04h>

Set acquisition range

<4>

Acquisition
Range

in 1 Hz steps, Max = 7.5 MHz, Min: Symbol rate/10 and when
demodulation is 8PSK min: Symbol rate/20


Opcode: <2A07h>

Set demodulation

<1>

Demodulation

0 = QPSK, 2 = 8PSK, 3 = 16QAM, 4 = 16APSK


Opcode: <2A08h>

Set inner FEC rate

<1>

Inner FEC Rate

1 = 1/2 Rate, 2 = 2/3 Rate, 3 = 3/4 Rate, 4 = 5/6 Rate, 5 = 7/8
Rate, 8 = 8/9 Rate, 9 = 9/10, 10=10/11 Rate, 11=11/12 Rate,
12 = 3/5, 13 = 4/5, 14 = 6/7 Rate, 15 = Reserved, 16 =
Reserved, 17 = Reserved


Opcode: <2A0Bh>

Set network specification

<1>

Network
Specification

0 = DVB 1 = DVB-S2 2 = DirecTV AMC