+12V monitor with implied decimal point.
Example: a value of 119 represents +11.9 Volts.
"
::= { monitor 3 }

minus12Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (-255..0)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
-12V monitor with implied decimal point.
Example: a value of -122 represents -12.2 Volts.
"
::= { monitor 4 }

plus24Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (0..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
+24V monitor with implied decimal point.
Example: a value of 242 represents +24.2 Volts.
"
::= { monitor 5 }

spectrumStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inverts the symbol mapping direction of rotation.
"
::= { monitor 6 }

lastRateCtrlStatus OBJECT-TYPE
SYNTAX INTEGER {
symbol(1),
data(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Last rate control can be set to auto, symbol or data, this
value indicates what is actually being used
"
::= { monitor 7}

inputLevel OBJECT-TYPE
SYNTAX RadPowerLevel (-1000..0)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Signal input level detected by the demodulator, in tenth of a dBm.
Example: a value of -740 represents an input level of -74.0 dBm
"
::= { monitor 8 }