DD240XR High-Speed Digital Demodulator

User Interfaces

MN-DD240XR – Rev. E

4-19

Fail indicates the EDI has not received an ARP reply to
its ARP requests and thus has not been able to resolve
the destination MAC address.

ETH LINK

{Pass/Fail}
Fail indicates that the Ethernet Data Interface has not
been able to establish a valid physical connection on its
Ethernet data port.

COMMON (Menu):


+5V SUPPLY:

{Pass/Fail}

The +5 V Supply is currently or has alarmed since last
clearing.


+12V SUPPLY:

{Pass/Fail}

The +12 V Supply is currently or has alarmed since last
clearing.


-12V SUPPLY:

{Pass/Fail}

-12 V Supply is currently or has alarmed since last
clearing. Only on units with a HSSI or ECL BAL/UNBAL
Terrestrial Interface installed.


+24V SUPPLY:

{Pass/Fail}

The +24 V Supply is currently or has alarmed since last
clearing.


DEMOD HW FAULT:

{Pass/Fail}



CLEAR LATCHED ALARMS: {False/True}

This screen is used to clear all latched alarms.

4.2.6

System Menu Options and Parameters


The System Screens are shown in Figure 4-10. These include:

DATE (MM/DD/YY):

Displays the current date.


TIME (HH:MM:SS):

Displays the current time.


FRONT PANEL (Menu):

BKLT LEVEL:

{HIGH, MED, LOW, OFF}

Sets the backlight intensity level.


BKLT TIMEOUT:

{0 – 99}

Allows the user to enter the amount of time in seconds
for the backlight to dim. Enter ‘0’ for no timeout.



KEY CLICK:

{ON, OFF}

Allows the user to choose between silent and audible
button depression.