Comtech EF Data DD240XR Rev Е User Manual

Page 81

Advertising
background image

DD240XR High-Speed Digital Demodulator

User Interfaces

MN-DD240XR – Rev. E

4-61

-----------------------------------------------------------------------------
-- alarms

majorAlarms OBJECT-TYPE
SYNTAX BITS {
signalLock(0),
synthPLL(1),
inputLevel(2),
clockActivity(3),
carrierCommunication(4),
demodCommunication(5),
fpgaConfiguration(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.
"
::= { alarms 1 }

majorAlarmsAllowed OBJECT-TYPE
SYNTAX BITS {
signalLock(0),
synthPLL(1),
inputLevel(2),
clockActivity(3),
carrierCommunication(4),
demodCommunication(5),
fpgaConfiguration(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
A bit field. Major alarms allowed.
"
::= { alarms 2 }

minorAlarms OBJECT-TYPE
SYNTAX BITS {
dataActivity(0),
buffUnderflow(1),
buffNearEmpty(2),
buffNearFull(3),
buffOverflow(4),
excClock(5),
excPllLock(6),
demodLock(7),
ifecLock(8),
ofecLock(9),
frameSync(10),
ebno(11),
terrEthDestIp(12),
terrEthLinkStatus(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
A bit field. On startup, the agent initializes these to a '0'B value.
"
::= { alarms 3 }

minorAlarmsAllowed OBJECT-TYPE
SYNTAX BITS {
dataActivity(0),

Advertising