parallel(6),
parallelM2P(7),
parallelDVB(8),
g703_E3(9),
g703_T3(10),
g703_E2(11),
g703_T2(12),
g703_T2Balanced(13),
g703_E1Balanced(14),
g703_E1(15),
g703_T1_AMI_BALANCED(16),
g703_T1_B8ZS_BALANCED(17),
g703sts_1(18),
oc3(19),
stm1(20),
directv(21),
directpc(22),
eclBalancedUnbalanced(23),
gigEthernet(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects the various interface types.
Only some interface cards have multiple types and these cards will
allow selections only within their capability.
"
::= { interface 1 }

terrFraming OBJECT-TYPE
SYNTAX INTEGER {
framing_None(187),
framing_188_Byte(188),
framing_204_Byte(204)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
'187' byte -- unframed transport stream input.
'188' byte DVB -- framed transport stream input,
'204' byte DVB -- framed transport stream input,
Changing the framing mode will effect the symbol rate and/or data rate.
"
::= { interface 2 }

terrStreaming OBJECT-TYPE
SYNTAX INTEGER {
packet(1),
continuous(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
'1' packet mode is the default interface method of dvb transmissionselects (187 Byte) unframed transport
stream input.
'2' continuous byte output -- bytes are transmitted as they are received, this provides an evenly spaced byte
gap
This parameter may only be available on some interfaces and some interface types.
"
::= { interface 3 }

-- terrByteGap OBJECT-TYPE
-- SYNTAX Unsigned32 (0..255)
-- MAX-ACCESS read-write