Comtech EF Data DD240XR Rev Е User Manual

Page 70

Advertising
background image

User Interfaces

DD240XR High-Speed Digital Demodulator

4-50

MN-DD240XR – Rev. E

SYNTAX INTEGER {
none(0),
viterbi1_2(1),
viterbi2_3(2),
viterbi3_4(3),
viterbi4_5(4),
viterbi5_6(5),
viterbi6_7(6),
viterbi7_8(7),
viterbi8_9(8),
viterbi9_10(9),
viterbi10_11(10),
viterbi11_12(11),
viterbi3_5(12),
viterbi4_5(13),
viterbi6_7(14)
viterbi1_4(15),
viterbi1_3(16),
viterbi2_5(17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects Inner FEC code rate type.
Changing the encoder will affect symbol rate and data rate.
Valid values include:
QPSK - viterbi1_2(1), viterbi2_3(2), viterbi3_4(3), viterbi5_6(5), viterbi7_8(7)
8PSK - viterbi2_3(2), viterbi5_6(5), viterbi8_9(8)
16QAM - viterbi3_4(3), viterbi7_8(7)
Unsupported choices include:
none(0), viterbi4_5(4),viterbi6_7(6), viterbi9_10(9),viterbi10_11(10),viterbi11_12(11)
viterbi1_4(15), viterbi1_3(16), viterbi2_5(17)
"
::= { demodulator 4 }

-- outerFecRate OBJECT-TYPE
-- SYNTAX RadRatio
-- MAX-ACCESS read-write
-- STATUS optional
-- DESCRIPTION
-- "
-- OID Reserved -- for the Outer FEC ratio
-- "
-- ::= { demodulator 5 }
--
-- outerFecBypass OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(0),
-- enable(1)
-- }
-- MAX-ACCESS read-write
-- STATUS optional
-- DESCRIPTION
-- "
-- OID Reserved -- disables or enables the Reed-Solomon decoder
-- "
-- ::= { demodulator 6 }
--
-- scrambler OBJECT-TYPE
-- SYNTAX INTEGER {
-- none(0),
-- ibs(1),
-- v35Iess(2),
-- v35Ccitt(3),
-- v35EfData(4),
-- v35Fairchild(5),

Advertising