Comtech EF Data DD240XR Rev Е User Manual

Page 71

Advertising
background image

DD240XR High-Speed Digital Demodulator

User Interfaces

MN-DD240XR – Rev. E

4-51

-- v35Om73(6),
-- rs(7),
-- rsEfData(8),
-- dvb(9)
-- }
-- MAX-ACCESS read-write
-- STATUS optional
-- DESCRIPTION
-- "
-- Reserved -- selects a scrambler type
-- "
-- ::= { demodulator 7 }
--
-- interleaver OBJECT-TYPE
-- SYNTAX INTEGER ( 15|29|30|58 )
-- MAX-ACCESS read-write
-- STATUS optional
-- DESCRIPTION
-- "
-- Reserved -- selects an interleave branch count
-- "
-- ::= { demodulator 8 }
--
-- interleaverBypass OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(0),
-- enable(1)
-- }
-- MAX-ACCESS read-write
-- STATUS optional
-- DESCRIPTION
-- "
-- Reserved -- Disables/enables the interleaver.
-- "
-- ::= { demodulator 9 }

dataRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects the data rate in bps.
The data rate may be constrained to specific values, depending
upon the terrestrial interface installed.
The data rate and the symbol rate are co-dependent and must both
stay within the operational parameters of the demodulator.
"
::= { demodulator 10 }

symbolRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects the symbol rate in sps.
The symbol rate may be constrained to specific values, depending
upon the terrestrial interface installed.
The data rate and the symbol rate are co-dependent and must both
stay within the operational parameters of the demodulator.
"
::= { demodulator 11 }

spectrum OBJECT-TYPE
SYNTAX INTEGER {
autoDetect(0),

Advertising