Electrical Interfaces

DD240XR High-Speed Digital Demodulator

5-4

MN-DD240XR – Rev. E

Table 5-2. Alarm Indications

Alarm

Pin Description

None

1 – 2 shorted, 7 – 8 shorted, open collector output driven low

Minor

1 – 2 shorted, 8 – 9 shorted, open collector output driven low

Major

2 – 3 shorted, 7 – 8 shorted, open collector output open

5.5 Remote Port (J4)


The Remote Port Interface (J4) can be used for the monitor & control functions of the unit. The
physical interface is a female 9-Pin D-Sub Connector. This bi-directional port complies with
RS-485 Electrical Specifications. Refer to Section 7.6 for protocol and programming details. Pin
outs are listed in Table 5-3.

Table 5-3. J4 - RS-485 Remote Control- 9-Pin ‘D’ Female

Pin No.

Signal

Description

Direction

1

Tx (B)

Transmit Data (+)

Output

5

GND

Ground

-

6

Tx (A)

Transmit Data (-)

Output

8

Rx (B)

Receive Data (+)

Input

9

Rx (A)

Receive Data (-)

Input


5.6 Terminal Port (J5)


The Terminal Port Interface (J5) can be used for the monitor & control functions of the unit. The
physical interface is a female 9-Pin D-Sub Connector. This bi-directional port complies with
RS-232 Electrical Specifications. Refer to Section 4.6 for terminal interface details. The pinouts
are listed in Table 5-4.

Table 5-4. J5 - RS-232 Terminal Port - 9-Pin ‘D’ Female

Pin No.

Signal Name

Description

Direction

3

TxD

Transmit Data

Output

2

RxD

Receive Data

Input

5

GND

Ground

---


5.7 RX RF IN (L-Band) (J6)


The Receive RF In (L-Band) (J6) Port is the L-Band input for the DD240 L-Band, 950 – 2150 MHz
tuning ra

nge through a 75Ω Female F-Type Connector.

5.8 RX IF IN (J7)

The RF Port is a 75Ω Female BNC-Type Connector, and the tuning range is 50 – 180 MHz.