User Interfaces

DD240XR High-Speed Digital Demodulator

4-16

MN-DD240XR – Rev. E

This screen is used to enable/disable alarms when the
demodulator has lost lock.



IFEC LOCK:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
Inner Forward Error Correction has encountered too
many errors.


OFEC LOCK:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
Outer Forward Error Correction has encountered too
many errors.


FRAME SYNC:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
DVB Frame Sync Byte (0 x 47) is not recovered from the
Input Stream.


EBNO:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
Eb/No value has fallen below the floor alarm value.


IP DEST ADDR

{Unmasked/Masked}}
Fail indicates the EDI has not received an ARP reply to
its ARP requests and thus has not been able to resolve
the destination MAC address.


ETH LINK

{Unmasked/Masked}
Fail indicates that the Ethernet Data Interface has not
been able to establish a valid physical connection on its
Ethernet data port.


COMMON (Menu):


+5V SUPPLY:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
+5 V Power Supply has drifted outside specifications.


+12V SUPPLY:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
+12 V Power Supply has drifted outside specifications.


-12V SUPPLY:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
-12 V Power Supply has drifted outside specifications.
Only on units with a HSSI or ECL BAL/UNBAL Terrestrial
Interface installed.


+24V SUPPLY:

{Pass/Fail, Unmasked/Masked}

This screen is used to enable/disable alarms when the
+24 V Power Supply has drifted outside specifications.


DEMOD HW FAULT:

{Pass/Fail, Unmasked/Masked}