Comtech EF Data DD240XR Rev Е User Manual

Page 62

Advertising
background image

User Interfaces

DD240XR High-Speed Digital Demodulator

4-42

MN-DD240XR – Rev. E





Opcode: <2406h>

Query Latched alarms and

Opcode: <2409h>

Query Current Alarms

Response

<1>













<1>




<1>









<1>









<1>

Major Alarms 1













Major Alarms 2




Minor Alarms 1









Minor Alarms 2









Common Faults

Bit 0 = loss of signal lock
Bit 1 = loss of synthesizer PLL lock
Bit 2 = input level alarm
Bit 3 = reserved for POST alarm
Bit 4 = FPGA Configuration alarm
Bit 5 = reserved for deframer FIFO fault
Bit 6 = reserved for deframer PLL lock fault
Bit 7 = carrier subsystem comm fault
0 = no alarm, 1 = alarm





Bit 0 = demod subsystem comm Fault
Bit 1 = loss of clock activity
Bit 2-7 = reserved
0 = no alarm, 1 = alarm

Bit 0 = reserved for loss of buffer clock
Bit 1 = loss of Rx data activity
Bit 2 = loss of demodulation lock
Bit 3 = loss of inner FEC lock
Bit 4 = loss of outer FEC lock
Bit 5 = loss of dvb frame lock
Bit 6 = Eb/No alarm
Bit 7 = reserved
0 = no alarm, 1 = alarm

Bit 0 = terrestrial buffer underflow
Bit 1 = terrestrial buffer overflow
Bit 2 = terrestrial buffer near empty
Bit 3 = terrestrial buffer near full
Bit 4 = exc clock activity
Bit 5 = loss of exc pll lock
Bit 6 = Ethernet Dest ID
Bit 7 = Ethernet Link Status
0 = no alarm, 1 = alarm

Bit 0 = -12 V alarm
Bit 1 = +12 V alarm
Bit 2 = +5 V alarm
Bit 3 = +24 V alarm
Bit 4 = reserved for temperature alarm
Bit 5 = LNB DC Supply
Bit 6 = Demod HW Fault
Bit 7 = reserved
0 = no alarm, 1 = alarm

Advertising