Comtech EF Data DD240XR Rev Е User Manual

Page 73

Advertising
background image

DD240XR High-Speed Digital Demodulator

User Interfaces

MN-DD240XR – Rev. E

4-53

MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Ebno floor limit in db from 01.00 to 15.00. There is an implied decimal point.
Example: a value of 1234 represents a floor limit of +12.34 dB
"
::= { demodulator 17 }

radPilotSymbolsEnabled OBJECT-TYPE
SYNTAX INTEGER {
withoutPilots(0),
withPilots(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables Pilots in DVB-S2."
::= { demodulator 18 }

radPlHeaderScramSeqIndex OBJECT-TYPE
SYNTAX INTEGER (0..999)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects PL Scrambler index."
::= { demodulator 19 }

radGoldSeqIndex OBJECT-TYPE
SYNTAX INTEGER (0..262142)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects Gold Code index."
::= { demodulator 20 }
radSatFraming OBJECT-TYPE
SYNTAX INTEGER {
no_sat_framing(0),
sat_framing_96k(1),
sat_framing_1_5(2)
sat_framing_dvb(3),
sat_framing_dss_direcpc(4),
sat_framing_dss_directv(5)
sat_framing_normal(6),
sat_framing_short(7),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Determines satellite framing
"
::= { demodulator 21 }



-----------------------------------------------------------------------------
-- interface

interfaceType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
asi(1),
aasi(2),
hssi(3),
rs422Serial(4),
v35Serial(5),

Advertising