HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Appendix B

Revision 8

B–9

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e., ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

query

(Target to

Controller)

Set Backup

Offset

SBO=

7 bytes,

numerical

Command or Query.

Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:2 redundancy system

so power is equal between the online and offline units when a switchover occurs. In the form

#,xx.xx where:

# = 1 or 2

xx.xx = level, in 0.25 dB increments

Examples: SBO=1,02.00’cr’ or SBO=2,02.50’cr’

SBO=

SBO?

SBO*

SBO?

SBO=#,xx.xx

(See Description of

Arguments for

details)