Comtech EF Data HPOD User Manual
Page 139
![background image](/files/778917/content/doc139.png)
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
MN/HPOD.IOM
Appendix B
Revision 8
B–9
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Set Backup
Offset
SBO=
7 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:2 redundancy system
so power is equal between the online and offline units when a switchover occurs. In the form
#,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples: SBO=1,02.00’cr’ or SBO=2,02.50’cr’
SBO=
SBO?
SBO*
SBO?
SBO=#,xx.xx
(See Description of