Comtech EF Data HPOD User Manual

Page 85

Advertising
background image

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Serial-Based Remote Product Management

Revision 8

5–15

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction

& Qualifier)

Response to Query

Retrieve Alarm

Status

N/A

117 bytes,

alphanumeric

Query only.

Reports the Alarm status of the unit.

Example:

<1/RAS?’cr’

>0001/RAS=’cr’’lf’

P24VT=OK’cr’

P15VT=OK’cr’

P10V1=OK’cr’

P10V2=OK’cr’

P7V5T=OK’cr’

P5VLT=OK’cr’

N5VLT=OK’cr’

FAN#1=OK’cr’

FAN#2=OK’cr’

HSTMP=OK’cr’

SHTDN=OK’cr’

IICST=OK’cr’

FPOUT=OK’cr’’lf’

Note: BUC=XX, and REF=XX will appear in the list if the BUC, and reference oscillator are installed.

N/A

RAS?

RAS=x….x

(See Description of

Arguments)

Retrieve

Configuration

Status

N/A

45 bytes,

alphanumeric

Query only.

Reports the configuration status of the unit.

Example:

<1/RCS?’cr’

>0001/RCS=’cr’’lf’

ATT=12.75’cr’ (Attenuation in dB)

AMP=1’cr’ (RF power amplifier state, 0=OFF, 1=ON)

MUT=1’cr’ (RF mute state, 0=un-muted, 1=muted)

ONL=1’cr’ (Online status for redundancy)

RED=1-1’cr’ (Redundancy state and mode, states: 0=OFF, 1=ON, modes: 0=manual, 1=auto)

GOF=00.00’cr’ (Gain Offset in dB)

AFR=1’cr’’lf’ (Auto Fault Recovery, 0=manual, 1=auto)

N/A

RCS?

RCS=x….x

(See Description of

Arguments)

Redundancy

State

RED=

1 byte,

value of 0, 1, 2

Command or Query.

Set or report as ON or OFF the redundancy state, in the form x, where:

0 = Off

1 = 1:1 Redundancy

2 = 1:2 Redundancy

Example:

<1/RED=1’cr’

>0001/RED=’cr’’lf’

RED=

RED?

RED*

RED?

RED =x