Comtech EF Data HPOD User Manual

Page 88

Advertising
background image

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Serial-Based Remote Product Management

Revision 8

5–18

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction

& Qualifier)

Response to Query

Summary Fault

Status

N/A

1 byte,

value of 0,1

Query only.

Returns the condition of the summary fault relay where:

0 = Not Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NO J6 pin L, and SumFLT_NC J6 pin

M is open)

1 = Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M, and SumFLT_NO J6 pin L is

open)

Example: <1/SFS?

>0001/SFS=0’cr’’lf’

N/A

SFS?

SFS=x

(See Description of

Arguments)

Remote

Address

SPA=

4 bytes,

numeric

Command or Query.

Set Physical Address in the form xxxx, where:

xxxx = address between 0001 to 9999, resolution 0001

Example: SPA=0412’cr’

SPA=

SPA?

SPA?

SPA=xxxx

(See Description of

Arguments)

Set RTC Time TIM=

6 bytes,

numeric

Command or Query.

Sets or returns the RTC time in the form hhmmss, where:

hh = hours, between 00 and 23;

mm = minutes, between 00 and 59,

ss = seconds, between 00 and 59

Example:(time = 23 hours, 12 minutes and 59 seconds since midnight.):

<1/TIM=231259’cr’

>0001/TIM=’cr’’lf’

TIM =

TIM?

TIM*

TIM?

TIM=xxxxxx

(See Description of

Arguments)

Retrieve

Number of

unread

Stored Alarms

N/A

2 bytes,

numeric,

00 to 99

Query only.

Returns the number of stored events that remain unread in the alarm log, in the form xx, where:

Xx = A maximum of 99 events may be stored in the alarm log.

Example:

<1/TNA? ’cr’

>0001/TNA=14’cr’’lf’

N/A

TNA?

TNA=xx

(See Description of

Arguments)

Terminal Status

change

N/A

1 byte,

value of 0,1

Query only.

Indicates if there has been a change in the terminal status since the last time the command was given. A

value of 0 indicates no status change, and a value of 1 indicates there has been a terminal status change.

Example:

<1/TSC?’cr’

>0001/TSC=0’cr’’lf’

N/A

TSC?

TSC=x

(See Description of

Arguments)

Software Image IMG=

1 byte

Command or Query.

Current Active software image, in the form x, where:

1=Bulk Image # 1 currently active

2=Bulk Image # 2 currently active

Example: IMG=1 (which is Image #1 active)

IMG=

IMG?

IMG*

IMG#

IMG?

IMG=x

(See Description of

Arguments)