Comtech EF Data HPOD User Manual
Page 84
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
MN/HPOD.IOM
Serial-Based Remote Product Management
Revision 8
5–14
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Retrieve next 5
unread Stored
Alarms
N/A
145 bytes,
alphanumeric
Query only.
Reports the five oldest stored events in the alarm log, and if there are no events in the log the unit will
reply with LNA*. All events that are read from the log are also automatically removed from the log.
Reply format:
YYYYYYYYYY ZZ mmddyy hhmmss’cr’
YYYYYYYYYY ZZ mmddyy hhmmss’cr’
YYYYYYYYYY ZZ mmddyy hhmmss’cr’
YYYYYYYYYY ZZ mmddyy hhmmss’cr’
YYYYYYYYYY ZZ mmddyy hhmmss’cr’’lf’
Where:
YYYYYYYYYY is the fault description.
ZZ is the event type:
FT = Fault
OK = Clear
IF = Information
mmddyy hhmmss = date / time stamp.
Example:
<1/LNA?’cr’
>0001/LNA=’cr’
LOG CLR IF 175503 052307’cr’
FAN #1 FT 175504 052307’cr’
OVR TMP FT 175504 052307’cr’
FAN #1 OK 175504 052307’cr’
IIC BUS FT 175504 052307’cr’’lf’
N/A
LNA?
LNA=YY..ss
(See Description of
Arguments)