Retrieve next 5

unread Stored

Alarms

N/A

145 bytes,

alphanumeric

Query only.

Reports the five oldest stored events in the alarm log, and if there are no events in the log the unit will

reply with LNA*. All events that are read from the log are also automatically removed from the log.

Reply format:

YYYYYYYYYY ZZ mmddyy hhmmss’cr’

YYYYYYYYYY ZZ mmddyy hhmmss’cr’

YYYYYYYYYY ZZ mmddyy hhmmss’cr’

YYYYYYYYYY ZZ mmddyy hhmmss’cr’

YYYYYYYYYY ZZ mmddyy hhmmss’cr’’lf’

Where:

YYYYYYYYYY is the fault description.

ZZ is the event type:

FT = Fault

OK = Clear

IF = Information

mmddyy hhmmss = date / time stamp.

Example:

<1/LNA?’cr’

>0001/LNA=’cr’

LOG CLR IF 175503 052307’cr’

FAN #1 FT 175504 052307’cr’

OVR TMP FT 175504 052307’cr’

FAN #1 OK 175504 052307’cr’

IIC BUS FT 175504 052307’cr’’lf’