HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Serial-Based Remote Product Management

Revision 8

5–17

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction

& Qualifier)

Response to Query

Retrieve

Maintenance

Status

N/A

168 bytes,

alpha- numeric

Query only.

Returns the maintenance status of the unit.

Example:

<1/RMS?’cr’

>0001/RMS=’cr’

P24VT=024.1’cr’

P15VT=015.2’cr’

P10V1=010.4’cr’

P10V2=010.4’cr’

P7V5T=007.8’cr’

P5VLT=005.8’cr’

N5VLT=-05.7’cr’

FANR1=100.0’cr’

FANR2=100.0’cr’

ATEMP=+40.0’cr’

A10V1=010.2’cr’

A10V2=010.2’cr’

FWPWR=+37.6’cr’

RVPWR=02.0’cr’’If’ (optional)

*Note: REFV will appear if REF OSC module is installed.

N/A

RMS?

RMS=x….x

(See Description of

Arguments)

Serial Number N/A

9 bytes,

numeric,

000000000 to

999999999

Query only.

Returns the unit’s 9 digit serial number in the form xxxxxxxxx.

Example:

<1/RSN?’cr’

>0001/RSN=072282040’cr’’lf’

N/A

RSN?

RSN=xxxxxxxxx

(See Description of

Arguments)

Retrieve Utility

Status

N/A

27 bytes,

alpha- numeric

Query only.

Returns the utility status of the unit.

Example:

RUS=’cr’

ADR=0001’cr’

BDR=9600’cr’

N/A

RUS?

RUS=x….x

(See Description of

Arguments)

Remote Baud

Rate

SBR=

4 bytes,

alphanumeric

Command or Query.

Set remote baud rate in the form xxxx, where:

9600 = 9600 baud

19K2 = 19200 baud

Example: SBR=9600’cr’

Note: When changing baud rates remotely the response to the command will be returned using the same

baud rate as that used to send the command.

SBR=

SBR?

SBR?

SBR=xxxx

(See Description of

Arguments)