HPOD C, X-, or Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Ethernet-based Remote Product Management

Revision 8

4–16

Amplifier – Use the drop-down list to set the amplifier as On or Off.


Mute – Use the drop-down list to set the Mute function as Enabled or Disabled.

Click [Change Configuration] to save these settings, or click [Reset] to revert to the previously

assigned Amplifier settings.

Fault Recovery

Use the drop-down list to set Fault Recovery as Automatic or Manual, and then click [Change].

BUC Mute

Use the drop-down list to set BUC Mute as Muted or Not Muted, and then click [Change].

Reference Adjust

Enter a numeric value from 0 to 255 to set the reference oscillator tuning voltage. The default

voltage value is 87. Click [Change] when done.

Serial

Remote Address – Enter a physical remote address from 0001 to 9999.

Baud Rate – Use the drop-down list to set the operating baud rate as 9600 or 19200 bps.

Click [Change Serial Configuration] to save these settings.