B.4.2 operation – Comtech EF Data HPOD User Manual

Page 141

Advertising
background image

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Appendix B

Revision 8

B–11

B.4.2 Operation

Task

Procedure

1

Set both units to “Auto” redundancy mode by sending them RAM=1 command.

2

Establish the current online status by sending each unit an ONL? query. Note one unit should return

ONL=1 (online), and one unit should return ONL=0 (offline)

3

Fail the unit that reported ONL=1. The switch should throw. Restore the unit

4

Repeat the ONL? query to both units. The unit that was failed in step 2 should now report ONL=0 and the

other should report ONL=1. Fail this unit and confirm the switch transitions.

5

Put the system in “Manual” mode by sending RAM=0 commands to both units.

6

The “SSW” command will force the switch to point to the selected unit. For example, an “SSW=1”

command will force the switch to point to SSPA 1 no matter which SSPA the command was issued to.

Ensure either unit can throw the switch in both directions by sending the following commands:

<1/SSW=1 (the switch may or may not transition)

<1/SSW=2 (the switch should transition)

<1/SSW=1 (the switch should transition)

<2/SSW=2 (the switch should transition)

<2/SSW=1 (the switch should transition)