HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

Serial-Based Remote Product Management

Revision 8

5–13

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction

& Qualifier)

Response to Query

Concise Utility

Status

N/A

11 bytes,

alphanumeric

Query only.

Reports the Maintenance status of the unit. Response is comma delimited in the form aaaa,bbbb,ccc,’cr’’lf’

where:

aaaa = Remote Unit Address

bbbb = Remote Baud Rate

N/A

CUS?

CUS=x….x

(See Description of

Arguments)

Set RTC (Real-

Time-Clock)

Date

DAT=

6 bytes,

numeric

Command or Query.

Set clocks in the form mmddyy, where:

mm = month of the year, between 01 and 12

dd = day of the month, between 01 and 31

yy = year, between 00 and 96 (2000 to 2096)

Example:(date = April 24, 2003):

<1/DAT=042503’cr’

>0001/DAT=’cr’’lf’

DAT=

DAT?

DAT*

DAT?

DAT=xxxxxx

(See Description of

Arguments)

Retrieve

Firmware

Number

N/A

256 bytes

Query only.

Returns the firmware type loaded into the unit.

Example: <1/FRW?’cr’

>0001/FRW=’cr’

BULK=FW12524’cr’

MnC =FW12522’cr’

FPGA=FW10788’cr’’lf’

Note: the RET? Query returns the MnC firmware revision.

N/A

FRW?

FRW=x…x

(See Description of

Arguments)

Mute State

MUT=

1 byte,

value of 0,1

Command or Query.

Mutes the unit, in the form x, where:

0 = Disabled

1 = Enabled

2 = Unit muted due to discrete control lines. Query response only.

Example: MUT=1’cr’

MUT=

MUT?

MUT*

MUT?

MUT=x

(See Description of

Arguments)

Online Status

ONL=

1 byte,

value of 0, 1

Command or Query.

Online status (applies only to redundancy), in the form x, where:

0 = Disabled

1 = Enabled

Example: <1/ONL=1’cr’

>0001/ONL=’cr’’lf’

ONL=

ONL?

ONL*

ONL?

ONL=x