2 ‘j6 | com1’ connector, 3 ‘j8 | input sample’ connector, 4 ‘j9 | output sample’ connector – Comtech EF Data HPOD User Manual

Page 34

Advertising
background image

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier

MN/HPOD.IOM

External Connectors and Pinouts

Revision 8

2–8

2.5.2 ‘J6 | COM1’ Connector

The ‘J6 | COM1’ Discrete Control connector is the primary input for controlling and monitoring

the SSPA. It is a 19-pin circular connector, type MS3112E14-19S. The pinout specification is

shown in Table 2-6.

Mating connector: ITT: KPT06J14-19P or MS3116J14-19P.

Table 2-6. ‘J6 | COM1’ Connector Pinout

Pin

Name

Description

A

RS485_+RX

B

RS485_-RX

C

RS485_+TX

D

RS485_-TX

E

RS232_RD

F

Ethernet TX+

G

RS232_TD

H

Ethernet TX-

J

Aux_Out

Not for customer use

K

SumFLT_COM

L

SumFLT_NO

Open when faulted, else tied to Pin K.

M

SumFLT_NC

When faulted, tied to Pin K, else open.

N

GND

P

ONLINE_Status

Not for customer use

R

+24V

Not for customer use

S

Mute Control

When AUX=1, system is muted until this pin is pulled to ground.

At that time, the unit unmutes. See the AUX remote command.

T

Minor_FLT_COM Reserved for future use

U

Ethernet RX-

V

Ethernet RX+

2.5.3 ‘J8 | INPUT SAMPLE’ Connector

The ‘J8 | INPUT SAMPLE’ port connector is a Type ‘N’ female. It provides a nominal –20 dB

sample of the input signal. A calibration label is provided near the connector that shows the

actual coupling values vs. frequency.

2.5.4 ‘J9 | OUTPUT SAMPLE’ Connector

The ‘J9 | OUTPUT SAMPLE’ port connector is a Type ‘N’ female. It provides a nominal -40 dB

sample of the output signal. A calibration label is provided near the connector that shows the

actual coupling values vs. frequency.

Advertising