Digi CM User Manual

Page 115

Advertising
background image

System Administration

Chapter 14

115

The alternative method to reset the unit is through the web interface. The web
interface provides the option of retaining the IP settings. To use the web
interface to reset the Digi CM, do the following:

1. Access the web interface.

2. System administration > Configuration management

3. Under Configuration import select Factory default.

.

4. Select the Configuration factory default options you want to restore from

the checklist.

5. Click

Import

. The Digi CM will automatically reboot.

The following are the default values when the Digi CM is reset to the factory
defaults.

Static IP Address: 192.168.161.5

Port Access Menu IP Address: 192.168.1.100

Port Access Menu TCP Port Number: 7000

Serial Port IP Address: 192.168.1.101-

Serial Port TCP Port Number: 7001-