System and Port Logging

Chapter 5

35

4. Enter the IP address of the primary and secondary (if applicable) syslog

server and select the syslog facility from the drop down menu.

5. Click

Save & apply

.

Enable A Compact-flash Card

The compact-flash card must be installed and configured on the Digi CM
before it can be used for system logging or storing Digi CM configuration
information. When storing log files to an external flash card, the size of the
available storage is dependent on both the size of the card and the port counts
of the Digi CM used. The maximum settings for log file sizes are listed in the
following table. See also Adding a Compact-flash Card on page 27.

Total Flash

Card Size

Digi CM

System Log

Port Log

(per port)

Total Memory

Used

32

8

4.6

3.1M

29M

16

4.6

1.53M

32

4.6

762K

48

4.6

500K

64

8

9.2

6.2M

58M

16

9.2

3.1M

32

9.2

1.53M

48

9.2

1.02M

128

8

18.4

12.3M

118M

16

18.4

6.2M

32

18.4

3.1M

48

18.4

2.0M

256

8

36.8

24.6M

236M

16

36.8

12.3M

32

36.8

6.2M

48

36.8

4.1M