Digi CM User Manual

Page 83

Advertising
background image

Rackable Systems Management Card

Chapter 10

83

.

Field

Description

Control

Power status

The first column shows the current state.
Three buttons are available to initiate an action to either, power
on, power off or restart the server. Dependant on the current sta-
tus Power on or Power off is disabled.

Reboot

Reboot the Rackable Server by sending a 500ms reset signal to
the server.

Connect

Spawn the Java Telnet applet or the local Telnet/SSH application
to connect directly to the port.

LED Mgmt

LED
Management

To control the LED in the front of the Rackable Server.
The first columns shows the current status of the LED. Three but-
tons are available to select the activity of the status LED: turn on,
turn off and blinking. Either of these buttons is disabled.

LCD Mgmt

Currently
displayed
message

Shows the message that is currently displayed on the LCD dis-
play.

Erase

This function clears the LCD display.
The saved message stays saved to flash.

Save

Save currently displayed message to flash memory.

Show saved
LCD message
upon startup

The first columns shows the current status: Yes or No.
This parameter defines which message is displayed upon startup
of the server, either the saved message or the standard: “Rack-
able Systems Phantom Vx.xx”.

Contrast

Set a contrast for the LCD panel.
The default is 50, the range is 0 – 100.

Phantom
Properties

Temperature

Indicates current temperature inside the Rackable Systems Server.

Power delay

Time in seconds before the server starts up after applying power
(0-98 seconds, 99 means no power on delay).

Power sense

The power sense option toggles between sensing server power
on the reset header or on the J7 connector. Most applications will
use the “Reset” option. This option should be set before shipping
from Rackable Systems, but may need to be reset if somehow
changed after shipping.

Communication
settings

Baud Rate

Configure the baud rate used to communicate with the Rackable
Systems Management Card. For this change to become effective
reset or power-cycle the Management card, and be sure to
switch the port settings in the Digi CM port settings.