3 product identification, 4 maintenance, 3 unit weights – Flowserve MX-85 Actuator User Manual

Page 13: 1 initial inspection and recording suggestions, 1 recommended maintenance, Limitorque actuation systems

Advertising
background image

Flow Control

Limitorque Actuation Systems

FCD LMAIM1341-00

MX-85/140 Maintenance and Spare Parts

5

Preferred Storage Orientation
Your MX actuator should be stored with the motor and terminal compartment in the horizontal position to obtain
optimum service life.

2.2.3 Unit Weights

Table 2.2 – Unit weights

Unit

lb.

kg

MX-85

259

117

MX-140

300

136

NOTE: Weights include stem nut and lubricant.

2.3 Product Identification

2.3.1 Initial Inspection and Recording Suggestions

Upon receipt of the actuator, several steps should be initially followed to ensure condition of equipment and to establish
proper record keeping.

1. After removing the actuator from the shipping carton or skid, thoroughly examine it for any physical damage which

may have occurred during shipment. If you note any damage, immediately report the damage to the transport
company and call Limitorque for further assistance.

2. A nameplate with important information is attached to each actuator. Record the following information for use when

you need to contact Limitorque with any questions about your actuator:

Unit type/size

Limitorque order number

Serial number

Figure 2.2 – Accutronix MX Nameplate

Unit

type/size

Limitorque

order no.

Serial

number

2.4 Maintenance

2.4.1 Recommended Maintenance

Under normal operating conditions, the MX is a maintenance-free actuator. Therefore, for normal applications, no
formal actuator maintenance is required; although visual inspection for oil leakage and excessive noise is recommended
every 1 million drive sleeve turns or every 3000 cycles. When conditions are severe, due to frequent operation or high

Advertising