STEP 11a AND 11b

Fit gear (#13-12) onto end of worm shaft. Ensure
both keys (#13-24) are in place in worm shaft.

11a

13-24

11b

13-12

STEP 12

Ensure gasket (#13-19) is in place on adapter
(#13-2).

12

STEP 13

Check that seal (#13-15), and ball bearings
(#13-11, 13-22, and 13-23) are correctly placed in
adapter (#13-2) and cap (#13-13).

Install handwheel spur cap assembly. Secure with
screws (#13-20). Remount handwheel (#13-10) if
removed with key (#13-7) and set screw (#13-18).