Flowserve MX-85 Actuator User Manual
Page 38
Advertising
Flow Control
Limitorque Actuation Systems
30
MX-85/140 Maintenance and Spare Parts
FCD LMAIM1341-00
STEP 11a AND 11b
Fit gear (#13-12) onto end of worm shaft. Ensure
both keys (#13-24) are in place in worm shaft.
11a
13-24
11b
13-12
STEP 12
Ensure gasket (#13-19) is in place on adapter
(#13-2).
12
STEP 13
Check that seal (#13-15), and ball bearings
(#13-11, 13-22, and 13-23) are correctly placed in
adapter (#13-2) and cap (#13-13).
Install handwheel spur cap assembly. Secure with
screws (#13-20). Remount handwheel (#13-10) if
removed with key (#13-7) and set screw (#13-18).
13
Advertising
This manual is related to the following products: