47

STEP 1

c

WARNING: Potential to operate while danger-
ous mechanical parts are exposed during
subassembly removal. To prevent injury, turn
off all power sources to actuator before remov-
ing handwheel worm gear assembly. Power
sources may include main power or control
power.

Remove the four screws (#1-33) from the retainer
plate (#1-32).

1

1-32

1-33

STEP 2

Lift off the retainer plate (#1-32).

2

STEP 3

Pull the handwheel worm gear assembly (#12) out
of the actuator housing.