1 removal – Flowserve MX-85 Actuator User Manual

Page 43

Advertising
background image

Flow Control

Limitorque Actuation Systems

FCD LMAIM1341-00

MX-85/140 Maintenance and Spare Parts

35

4.5.1 Removal

First Remove

1. Remove actuator from mounting adapter.

2. Drain oil.

3. Remove thrust base (subassembly #10) - if fitted.

4. Remove stem nut.

STEP 1

a

WARNING: Potential to operate while danger-
ous mechanical parts are exposed during
subassembly removal. To prevent injury, turn
off all power sources to actuator before remov-
ing base plate assembly. Power sources may
include main power or control power.

Using a hex key, remove the eight screws (#11-5).

1

11-5

STEP 2

Pull the baseplate (#11-1) off the drive sleeve.

c

WARNING: If handwheel worm gear assembly
has previously been removed,the drive sleeve
assembly may slip and fall out of housing.
Hold drive sleeve assembly in from opposite
end. See Sections 4.7.3 and 4.7.4 for optional
removal and remounting.

2a

11-1

2b