9 motor lead harness, 1 removal, Limitorque actuation systems – Flowserve MX-85 Actuator User Manual

Page 85: Flow control, Figure 5.9 – motor lead assembly

Advertising
background image

Flow Control

Limitorque Actuation Systems

FCD LMAIM1341-00

MX-85/140 Maintenance and Spare Parts

77

5.9 Motor Lead Harness

Figure 5.9 – Motor Lead Assembly





��
��
��

��

��

�����

��������
���������������

��

��


����������������

����������������

�������������

������������
�����������������

��

��

��

�������������

�����������������������

����

5.9.1 Removal

First Remove
1. Remove motor (subassembly #4). (See Section 4.1.1)

2. Remove Accutronix control panel (subassembly #7). (See Section 5.1.)

3. Remove control module (subassembly #15). (See Section 5.2.1)

4. Remove contactor assembly (subassembly #8). (See Section 5.6.1)

STEP 1

If worm shaft assembly (subassembly #3) is still
mounted in unit, remove the four screws (#3-9)
and rotate cap (CCW) to rotate cap tab away from
motor lead seal.

1

Cap

tab

Motor

lead

seal

STEP 2

Remove motor lead harness by threading the
harness back through housing and out motor
end. Work the three connectors out through the
hole/slot in the housing one at a time.

2

Advertising
This manual is related to the following products: