1 removal – Flowserve MX-85 Actuator User Manual

Page 76

Advertising
background image

Flow Control

Limitorque Actuation Systems

68

MX-85/140 Maintenance and Spare Parts

FCD LMAIM1341-00

5.6.1 Removal

First Remove
1. Remove motor (subassembly #4). (See Section 4.1.1.)

2. Remove Accutronix control panel (subassembly #7). (See Section 5.1.)

3. Remove control module (subassembly #8). (See Section 5.2.1.)

4. Remove terminal block (subassembly #15). (See Section 5.5.1.)

STEP 1

Using an M3 hex key, loosen the two 4 mm screws
(#8-28) that mount the contactor assembly to the
actuator.

1

8-28

STEP 2

Lift contactor assembly until the keyhole slots in
the contactor mounting plate allow the heads of the
M4 screws to pass through.

2

STEP 3

Remove the contactor assembly while threading the
motor power socket out of the motor compartment.

Disconnect connectors 4 and 5 to motor lead
harness.

3

Motor power plug

Advertising